Platform switching implant
- Author Details:
-
Sumedha Srivastava *
-
Veena Kalburgi
-
Kapil Jain
-
Pooja Bharadwaj
Introduction
To provide the patients with good oral health is the main purpose of the dentistry. In case of the patients who have few teeth or are completely edentulous have poor masticatory ability, esthetics and speech. Such patients wearing the removal partial denture or complete denture have their esthetics, masticatory ability reduced as compared to natural dentition. Considering all these factors, now a days implant is one of the better option in comparison to removable partial denture or complete denture. But one of the fact that should be kept in mind is the maintainance of crestal bone levels following implant placement. In case of traditional implants there is always a certain amount of crestal bone loss during first year after placement of implant because of inflammatory infiltrate that forms around the implant as well as due to violation of biologic width. This was first reported by Adell et al.[1] Apart from these two major factors, there are various minor factors that are associated with the crestal bone loss. These factors are the presence of microgap between implant and the abutment, traumatic surgical technique, shape and size of the abutment.
Hence the concept of platform switching (discovered accidently) was introduced and later on become one of the better optiob for the modern dentistry in relation to the preservation of crestal bone levels as it has the abutment that i s narrower than the implant that has wider collar. This type of connection has the ability to deal with various major and minor factors associated with crestal bone loss.
History
In 1980 wider diameter implants were used. This was the period were due to lacking of commercially available components, mismatched diameter implant and abutment were used. But later on it was found that due to this difference in the diameter of implant and abutment, there was a reduction in crestal bone loss (as firstly described by Lazzara, Porter, and gardner) who introduced the concept of platform switching implants in literature.
Rationale
Following the use of traditional implant, there is always certain amount of bone loss. To prevent this bone loss, there needs to be the movement of inflammatory cell infiltrate away(which is located 0.75mm above and 0.75 mm below the implant abutment junction) away from the crestal bone, increament in the surface area at the implant abutment junction (by horizontal and vertical extension of biologic width) and equal distribution of mechanical stress at the coronal portion of impant (hence reduction of microgap). But the traditional implant lack these characteristics as compared to platform switching implant which fulfill all these criteria and hence reduction of crestal bone loss. Thus this the main rationale to use the platform switching implant in dentistry in recent years.
Concept of platform switching
The implant is always surrounded by the soft tissue seal. This seal is present both laterally and apically. In case of two traditional implants, if they are placed close together, then it will result in increase vertical bone loss between the two implants. However in case of platform switching implant, due to difference in diameter of implant and abutment, when these two implants are placed together, it will result in horizontal and vertical extension of biologic width and as a result of which there will be the movement of microbes (and thus inflammatory cell infiltrate away from crestal bone), uniform distribution of stress in the centre of implant and thus preservation of crestal bone levels.

Microbiota associated with platform switching implant
It was found by Canullo et al[2] that the microbiota associated with the platform switching implant in was Streptococcus sanguis,mitis oralis V. Parvula, Actinomyces, P. gingivalis.
Indications
If the residual bone height is limited by the anatomic structures present.
If there is a need for the placement of shorter implants in the atrophic area.
When the distance between the two implants is less than 3 mm i.e. in the narrow edentulous ridge.
When aesthetics is of major concern.
Limitations
Normal size abutments require larger implants
Normal implants require smaller abutments as if it is not so then the esthetics would be compromised.
Three to four mm of soft tissue seal is essential for the platform switched implants to prevent the bone resorption.
Decreased abutment diameter can result in fracture of the abutment as because of smaller size abutment, stresses are more concentrated near the abutment.
Advantages
Since the abutment is smaller in diameter than the implant neck hence it helps to provide more effective soft tissue seal.
Equal distribution of stress.
Prevent or minimize the crestal bone resorption as the inflammatory infiltrate moves away from the crestal bone.
Results in a horizontal extension of the biologic width.
Provides bone support for shorter implants.
Platform switching implants can be placed in the area where aesthetics is of major concern.
Improved implant stability and thus enhanced longevity.
Disadvantages
Esthetics can be compromised if there is no sufficient space.
Similar design of the components is essential for the platform switched implants to function properly.
Non-platform switched to platform switched implants
Many factors should be considered while planning for the placement of implant. Various studies have been done by various researchers that gives us the indication that platform switching implants are one of the better option as compared to the traditional implants. A study was conducted by Markus Hurzeler et al [3] for the comparison of bone loss between platform switching implant and non platform switching implant and by his study he concluded that marginal bone loss was more in non platform switched implant as compared to platform switched implant. Vela N et al[4] conducted the study on the horizontal circular extension of biologic width and found that this extension was more in platform switching implant as compared to non platform switching implant. Amount of vertical bone loss was compared by Cappiello et al[5] and he found that it was minimal in platform switching implant as compared to non platform switched implants. Lazzara, Porter[6] during the 13 years radiographic period found that crestal bone loss was more in non platform switching implants as compared to platform switching implants. A study was conducted by Degidi[7] on the microgap of platform switching and non platform switching implants and he concluded that there was zero microgap in case of platform switching implants.
Discussion
The most important criteria for the implant to function successfully is the preservation of crestal bone levels. Traditional implants lack this criteria as there is always a certain amount of bone loss by these implants. Hence in this regard, platform switching implants are one of the better option to prevent the crestal bone loss by moving the inflammatory cell infiltrate away from the crestal bone, by preservation of biologic width and by reduction of microgap. Baumgarten et al [8] described the platform switching technique and its usefulness in situations where shorter implants must be used, where implants are placed in the esthetic zone and where a larger implant is desirable, but prosthetic space is limited. They believed that a sufficient tissue depth of approximately 3 mm or more is necessary to accommodate an adequate biologic width. Platform switching implant prevent the crestal bone loss and thus preserves the crestal bone. Cappiello et al[9] found that microgap is an important factor in the remodeling of peri-implant crestal bone and platform switching implant helps to reduce this microgap and thus preventing the crestal bone resorption.
Conclusion
One of the advantage of platform switching implant is the equal distribution of mechanical stress at the centre of the implant, horizontal and vertical extension of biologic width and moving inflammatory cell infiltrate away from the crestal bone thus preventing or minimizing the crestal bone loss. Platform switching implants has proved to be one of the better option in these recent years as it fulfill all the factors that are essential for the implant to function successfully.
Source of funding
None.
Conflict of interest
None.
References
- R Adell, U Lekholm, B Rockler, P I Branemark. A 15-year study of osseointegrated impants in the treatment of theedentulous jaw. Int J Oral Surg 1981. [Google Scholar]
- L Canullo, A Quaranta, R P Teles. The microbiota associated with implants restored with platform switching: A preliminary report. J Periodontal 2010. [Google Scholar]
- M Hurzeler, S Fickl, O Zuhur, HC Wachtel. Peri-implant bone level around implants with platform-switched abutments: Preliminary data from a prospective study. J Oral Maxillofac Surg 2007. [Google Scholar]
- N Vela. Benefits of fan implant platform modification technique to reduce crestal bone resorption. Implant Dent 2006. [Google Scholar]
- M Cappiello. Evaluation of Peri-implant bone loss around platform-switched implants. Int J Periodont Restorat Dent 2008. [Google Scholar]
- R J Lazzara, S S Porter. Platform switching: A new concept in implant dentistry for controlling post restorative crestal bone levels. Int J Periodontics Restorative Dent 2006. [Google Scholar]
- M Degidi, G lezzi, A Scarano, A Piatteli. Immediately loaded titanium implant with a tissue-stabilizing/maintaining design (beyond platform switch) retrieved from man after 4 weeks: A histological and histomorphometrical evaluation: A case report. Clin Oral Implants Res 2008. [Google Scholar]
- H Baumgarten. A new implant design for crestal bone preservation: Initial observations and case report. Pract Proced Aesthet Dent 2005. [Google Scholar]
- M Cappiello. Evaluation of Peri-implant bone loss around platform-switched implants. Int J Periodont Restorat Dent 2008. [Google Scholar]